Guide · Specialty coatings

Review the complete FEVE system.

Keep solid-colour, metallic and clear finishes connected to their supporting coats and stated conditions.

Protective coating on a bolted structural-steel connection

Choose the finish and supporting coats together

Substrate preparation, primer, intermediate coat, finish and application conditions form one coating system. Selecting a topcoat by finish alone does not confirm compatibility with the layers underneath it.

FEVE solid-colour topcoat

SC100

An ambient-curing FEVE fluorocarbon solid-colour topcoat for protective coating systems on steel structures.

Match the substrate preparation, compatible primer and intermediate coat, finish colour and application conditions as one coating system.

FEVE metallic topcoat

SC101

An ambient-curing FEVE fluorocarbon metallic-effect topcoat for protective coating systems, with its own finish-specific technical data.

Review the metallic appearance, compatible supporting coats, application equipment and required coating build together.

FEVE clearcoat

SC102

An ambient-curing FEVE fluorocarbon clear finish for a compatible protective coating system.

Select around the underlying coating, required appearance, service exposure and the application and curing schedule.

Read each finish's own data

Solid-colour, metallic and clear finishes retain their own technical values and conditions. Do not replace one finish's schedule with another. Surface-dry and hard-dry references are not a statement of complete cure.

Published system notes

SC100

  • Reference film data use a three-layer system: primer / intermediate / topcoat.
  • Film-property results relate to the stated system. Film thickness, substrate preparation and complete conditioning details are defined for the project.
  • Surface-dry and hard-dry times are not full chemical-cure or return-to-service times.
  • For black, phthalocyanine-green and phthalocyanine-blue single-colour topcoats, the reference minimum solids content is ≥30%. Agree a shade-specific solids target for blends using these colours.

Reference steel coating build: Epoxy zinc-rich primer + ambient-curing fluorocarbon topcoat; or epoxy zinc-rich primer + epoxy micaceous iron-oxide intermediate + topcoat, with an optional clearcoat.

Reference wall coating build: Primer + intermediate + ambient-curing fluorocarbon topcoat. Putty may be added or the intermediate coat omitted depending on the actual application.

SC101

  • Reference film data use a four-layer system: primer / intermediate / metallic topcoat / clearcoat.
  • Film-property results relate to the stated system. Film thickness, substrate preparation and complete conditioning details are defined for the project.
  • Surface-dry and hard-dry times are not full chemical-cure or return-to-service times.
  • For black, phthalocyanine-green and phthalocyanine-blue single-colour topcoats, the reference minimum solids content is ≥30%. Agree a shade-specific solids target for blends using these colours.

Reference steel coating build: Epoxy zinc-rich primer + ambient-curing fluorocarbon topcoat; or epoxy zinc-rich primer + epoxy micaceous iron-oxide intermediate + topcoat, with an optional clearcoat.

Reference wall coating build: Primer + intermediate + ambient-curing fluorocarbon topcoat. Putty may be added or the intermediate coat omitted depending on the actual application.

SC102

  • Reference film data use a four-layer system: primer / intermediate / solid-colour topcoat / clearcoat. The reference build uses the topcoat described under Linkium SC100.
  • Film-property results relate to the stated system. Film thickness, substrate preparation and complete conditioning details are defined for the project.
  • Surface-dry and hard-dry times are not full chemical-cure or return-to-service times.

Reference clearcoat placement: Clear finishing layer over a compatible fluorocarbon topcoat system.

Describe the coating line

  • Substrate and preparation, plus the existing primer or underlying coat.
  • Required solid colour, metallic appearance or clear finish.
  • Application method, intended coating build and service exposure.
  • Documents and test requirements for the selected coating system.

PVF steel drum lining is a separate application. FEVE topcoat data do not establish an internal-lining or food-contact claim.

Selection guidance based on the published Linkium catalogue. Confirm the selected-grade specification and applicable safety documents for your intended use.

Linkium assistantAI assistant · Product information

Hi, I am Linkium's AI assistant. Tell me your application, product or chemical specification and I can help you find relevant product information. To request a response from our team, use the contact form or WhatsApp. Prices, lead times and payment terms come from a person.

Messages are stored and sent to our AI provider. Avoid sensitive information. Privacy notice.

Prefer another channel? Email our team or use WhatsApp below.

Continue on WhatsApp